Anern Hybrid Solar Inverter 5KW / 6.5KW / 12KW | Pure Sine Wave | MPPT 120A | WiFi | 24V/48V | Off-Grid

|
AN-FGI-S6500 |
|
AC Input |
|
Rated Input Voltage(VAC) |
208/220/230/240;L+N+PE |
|
Voltage Range(VAC) |
90~280(APP mode);170~280(UPS mode) |
|
Frequency(Hz) |
50/60(Auto Adaptive) |
|
AC Output |
|
Rated Capacity(kW) |
6.5(Output Power rating will be reduced to 90%,when setting the Output Voltage to 208V) |
|
Surge Power(kVA) |
12 |
|
Voltage(VAC) |
208/220/230/240 |
|
Power Factor(PF) |
1 |
|
Frequency(Hz) |
50/60±0.1% |
|
Switch Time(ms) |
10(APP/UPS mode)/20(GEN mode) |
|
WaveForm |
Pure Sine Wave |
|
Overload Capacity(Battery Mode) |
1min@102%~110% load 10s@>110% load |
|
Max.Efficiency(Battery Mode) |
94%@48V |
|
Charger(PV/AC) |
|
Solar Charger Type |
MPPT |
|
Max PV Input Current/Power |
27A/9000W |
|
MPPT Range@Operating Voltage(VDC) |
60~450 |
|
PV Start-up Voltage |
80Vdc |
|
Max PV Open Circuit Voltage(VDC) |
500 |
|
Max PV Charge Current(A) |
120 |
|
Max AC Charge Current(A) |
120 |
|
Max.Charge Current(PV+AC)(A) |
120 |
|
Battery |
|
Nomal Voltage(VDC) |
48 |
|
Battery Type |
Lithium and Lead-acid |
|
General Data |
|
HMI |
LCD |
|
Interface |
RS232/RS485/CAN |
|
Monitoring |
WiFi(Optional) |
|
Ingress Protection |
IP21 |
|
Operating Temperature |
-10°C~60°C |
|
Relative Humidity |
5%~95%(Non-condensing) |
|
Storage Temperature |
-15°C~60°C |
|
Max.Operating Altitude |
4000m(Derating above 1000m) |

|
AN-FGI-S5000 |
|
AC Input |
|
Rated Input Voltage(VAC) |
208/220/230/240;L+N+PE |
|
Voltage Range(VAC) |
90~280(APP mode);170~280(UPS mode) |
|
Frequency(Hz) |
50/60(Auto Adaptive) |
|
AC Output |
|
Rated Capacity(kW) |
5(Output Power rating will be reduced to 90%,when setting the Output Voltage to 208V) |
|
Surge Power(kVA) |
10 |
|
Voltage(VAC) |
208/220/230/240 |
|
Power Factor(PF) |
1 |
|
Frequency(Hz) |
50/60±0.1% |
|
Switch Time(ms) |
10(APP/UPS mode)/20(GEN mode) |
|
WaveForm |
Pure Sine Wave |
|
Overload Capacity(Battery Mode) |
1min@102%~120% load 10s@>120% load |
|
Max.Efficiency(Battery Mode) |
93.5%@24V |
|
Charger(PV/AC) |
|
Solar Charger Type |
MPPT |
|
Max PV Input Current/Power |
27A/9000W |
|
MPPT Range@Operating Voltage(VDC) |
60~450 |
|
PV Start-up Voltage |
80Vdc |
|
Max PV Open Circuit Voltage(VDC) |
500 |
|
Max PV Charge Current(A) |
160 |
|
Max AC Charge Current(A) |
160 |
|
Max.Charge Current(PV+AC)(A) |
160 |
|
Battery |
|
Nomal Voltage(VDC) |
24 |
|
Battery Type |
Lithium and Lead-acid |
|
General Data |
|
HMI |
LCD |
|
Interface |
RS232/RS485/CAN |
|
Monitoring |
WiFi(Optional) |
|
Ingress Protection |
IP21 |
|
Operating Temperature |
-10°C~60°C |
|
Relative Humidity |
5%~95%(Non-condensing) |
|
Storage Temperature |
-15°C~60°C |
|
Max.Operating Altitude |
4000m(Derating above 1000m) |






Inverter use notice
1. The starting power of inductive load electrical appliances shall be at least three times of the rated power of the electrical appliances. If the starting power exceeds the inverter power, the inverter may be damaged. Please select a suitable model before purchasing.
2. Please connect the circuit correctly according to the instructions, and install switches for each circuit.
3. Starting sequence: first turn on the battery switch, start the inverter, and turn on the PV, mains and load switches.
4. Shutdown sequence: turn off the switches of load, PV and mains, turn off the inverter, and finally turn off the battery.
In order to achieve stable operation of the solar system and save electricity bill, it is recommended to connect the battery; when the mode is set to SBU, the system will use the PV and battery first and the utility last.